SERVICE MANUAL NUMBER 28
Speedometer Water Passage
Pickup Inspection and Cleaning
1. Inspect opening (pitot tube), on leading edge of gear housing, for obstruction. Clean
2. Inspect water passage seal for nicks, cuts or distortion. Replace if necessary.
90-863160 MAY 2000
opening with a short piece of wire. If obstruction can not be removed with wire, carefully
reopen tube using a 5/64 in. (2 mm) diameter drill bit. Do not drill beyond a depth of
2-7/16 in. (62 mm).
a -
Pitot Tube
a -
Water Passage Seal
BRAVO ONE GEAR HOUSING
a
a
22462
22085
Page 3B-29