SERVICE MANUAL NUMBER 28
110 Amp Fuse Test (Pump Out of Boat)
1. Connect the ohmmeter leads between the terminals on the fuse.
2. Zero Ohms Reading (Full Continuity)-Fuse OK.
20 Amp Fuse Test
1. Remove the fuse from the fuse holder.
90-863160 MAY 2000
a -
110 Amp Fuse (Red)
b -
Ohmmeter Leads
High Ohms Reading (No Continuity)-Replace fuse.
a -
Fuse Holder
a
a
OILDYNE TRIM PUMP
b
22493
22496
Page 5A-23