Tp Sensor Reset Procedure - Honda MUV700 big red Service Manual

Table of Contents

Advertisement

FUEL SYSTEM (PGM-FI)
MIL
IGNITION
SWITCH
6-52
TP SENSOR RESET
PROCEDURE
NOTE
:
Make sure that the DTC is not stored in
the
peM
memory. If the
DTe
is stored, the reset mode will
not start.
,. Remove the dummy connector from the OLe
{page6-12l,
Short
the
OLe
terminals
using
the
special tool.
TOOL:
SCS connector
070PZ·ZY30100
CON
NECTION:
Brown/
red
-
Green
2.
Disconnect
the
Eel
sensor 2P
black
connector.
Short the wire
harness
side connector terminals
with
a jumper wire.
3. Turn the ignition switch to ON (I).
The MIL stars
blinking
(reset
receiving
pattern).
Within
10
seconds
after
turning
the
ignition
switch to ON
(I),
disconnect
the jumper
wi re from
the 2P connector.
4. When the
reset
procedure is complete,
the MIL
blinking changes
from
Reset
Receiving Pattern
to
Confirmation Pattern.
Turn the ignition switch to OFF
(0).
If more than
10
seconds elapse or
the
procedures
are incorrect,
the
MIL stays on.
Repeat the reset
procedures.
Gj)
Within
10 sec.
0
U
- '
- - - -
-
U
l
;
ON
:
0.1 sec.
"
I~I'~'
- - " "
0.3 sec.
,
.
I
0.3 sec.
;---'---'
1,2
sec.
I
• _ _ _ _ _ ..J ___ _
Reset Receiving
Pattern
- - - - - -
! =
,'
='----'==-==-=~~.
Reset Confirmation Pattern
OFF
(Terminal side of
the wire harness)
(Stay on:
Reset
procedure is not complete)
ON
(I)
------
I
OFF
(0)