6. Connect the brown (Br) lead of the
starter relay to the positive battery termi-
nal and connect the black (B) lead to the
negative battery terminal. Check for con-
tinuity between the starter relay termi-
nals. Replace if there is no continuity.
7. Disconnect the brown (Br) or black (B)
lead of the starter relay from a battery
terminal. Check that there is no continuity
between the starter relay terminals.
Replace if there is continuity.
Br
8. Install the starter relay, and then connect
the battery cables, starter relay connec-
tor, and starter relay leads.
Ignition and ignition control
system

Checking the ignition spark

1. Disconnect the spark plug caps from the
spark plugs.
NOTE:
To prevent the engine from starting when
cranking it, be sure to disconnect both spark
plug caps.
2. Connect the spark plug cap to the special
service tool.
Ignition tester: 90890-06754
3. Crank the engine and check for a spark.
If there is no spark, check the ignition
system.
6AU3K11
Starting system / Ignition and ignition control system
WARNING
• Do not touch any of the connections of
the special service tool.
• Be sure to install the special service tool
to the spark plug cap so that sparks do
not leak out.
• Keep flammable gas or liquids away,
since this test can produce sparks.
B
NOTE:
S6AU8033
Repeat steps 2–3 for each spark plug cap.

Checking the spark plug cap

1. Remove the spark plug caps from the
spark plug wires by turning the caps
counterclockwise.
8
8
OK
1
2
S6AU8034
3
4
5
8
6
7
S6AG8030
8
9
8-30