Pt Electrical System; Checking The Fuse; Checking The Pt Relay - SELVA MARINE Pike 9,9 Service Manual

Table of Contents

Advertisement

NOTE:
• If the fluid is at the correct level, a small
amount of fluid should overflow out of the
filler hole when the cap is removed.
• If the fluid is below the correct level, add the
recommended PT fluid.
Recommended PT fluid:
ATF Dexron II
9. Install the reservoir cap, and then tighten
it to the specified torque.
NOTE:
If the fluid is below the correct level in step 8,
repeat steps 5–9 until the fluid remains at the
correct level.
Reservoir cap:
5 N·m (0.5 kgf·m, 3.7 ft·lb)

PT electrical system

Checking the fuse

1. Check the fuse for continuity. Replace if
there is no continuity.
NOTE:
• For the location of the fuse, see "Electrical
component and wiring harness routing" (8-
1).
• To check the fuse, see "Checking the fuse
(E model)" (8-26).

Checking the PT relay

1. Check the PT relay for continuity.
Replace if out of specification.
6AU3K11
PT cylinder / PT electrical system
2
1
2
B R
PT relay continuity
Black (B) 1 – Green (G) 3
Black (B) 1 – Blue (L) 4
Black (B) 1 –
7
Sky blue (Sb) 5
7
Black (B) 1 –
Light green (Lg) 6
Red (R) 2 – Green (G) 3
Red (R) 2 – Blue (L) 4
7
1
B
R
G
L
Sb
3
Lg
4
Sb
3
5
4
G
L
Lg
Sb
S6AU7106
Continuity
No continuity
1
2
Lg
6
3
4
5
6
7
8
9
7-54

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents