Installing The Lower Unit - SELVA MARINE Pike 9,9 Service Manual

Table of Contents

Advertisement

LOWR
4. Install the water pump housing assembly
7 into the lower case, and then install
the rubber seal 8.
9
9
LT
LT
572
LT
LT
572
CAUTION:
Do not turn the drive shaft counterclock-
wise, otherwise the water pump impeller
may be damaged.
NOTE:
• Apply grease to the inside of the water
pump housing.
• While turning the drive shaft clockwise,
push down on the water pump housing and
install it.
• Align the projections on the rubber seal 8
with the holes in the water pump housing.
5. Tighten the water pump housing bolts 9
and = to the specified torque.
Water pump housing bolt 9 and =:
18 N·m (1.8 kgf·m, 13.3 ft·lb)

Installing the lower unit

1. Set the shift lever to the R position. (H
model)
Set the remote control lever to the R
position. (R model)
2. Set the shift rod to the R position.
6-37
Lower unit
0
0
A A
S6AU6134
F
N
R
LT
LT
572
8
3. Install the lower unit to the upper case,
7
and then tighten the lower case mounting
bolts 1 to the specified torque.
2
NOTE:
• Before installing the lower unit to the upper
case, install the dowels 2 into the lower
case.
• Before installing the lower unit, make sure
that the locknut is removed from the shift
rod.
• When installing the lower unit, make sure
that the water pipe 3 is inserted securely
into the rubber seal 4.
Lower case mounting bolt 1:
4. Install the locknut 5, and then screw the
6
adjusting nut 6 onto the shift rod 7.
3
2
4
1
LT
LT
572
18 N·m (1.8 kgf·m, 13.3 ft·lb)
F
N
R
S6AU6135
S6AU6136
6AU3K11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents