SELVA MARINE Pike 9,9 Service Manual page 275

Table of Contents

Advertisement

G
G
B
NOTE:
• Do not use peak voltage adapter B when
measuring the Rectifier output peak volt-
age.
• Be sure to check the lighting coil before
measuring the Rectifier output peak volt-
age.
Rectifier output peak voltage:
Red (R) – Ground
Unloaded
r/min
1,500
DC V
13
2. Disconnect the Rectifier connector and
terminal.
3. Check
the
Rectifier
Replace if out of specification.
NOTE:
The voltage values given in the table are for
reference only. If voltage is produced, there
is continuity, and, if there is an overload,
there is no continuity. Refer to the table to
determine if there should or should not be
continuity and replace the Rectifier if out of
specification.
6AU3K11
G
R
G
1
S6AU8054
3,500
19
for
continuity.
Charging system (E model)
2
G
4
R
3
G
5
B
b
NOTE:
Be sure to set the measurement range a,
and display the mark b by pushing the
"SHIFT" switch when checking the Rectifier
continuity.
Rectifier continuity (testing diode)
Tester lead
Display value (V)
+
-
(reference data)
G 2
R 4
G 2
B 5
G 2
G 3
G 3
R 4
G 3
B 5
G 3
G 2
B 5
R 4
B 5
G 2
B 5
G 3
R 4
B 5
R 4
G 2
R 4
G 3
OL: Indicates an overload
B5
G2
G3
R4
S6AU8055
a
S6S18360
Conti-
nuity
0.416
Yes
OL
No
OL
No
0.415
Yes
OL
No
OL
No
0.849
Yes
0.487
Yes
0.492
Yes
OL
No
OL
No
OL
No
8-38
1
2
3
4
5
6
7
8
9