Checking The Charge Coil - SELVA MARINE Pike 9,9 Service Manual

Table of Contents

Advertisement

Pulser coil resistance (reference
data):
White/red (W/R) – Black (B)
240–360 Ω at 20 °C (68 °F)
4. Connect the pulser coil connectors.

Checking the charge coil

1. Measure the charge coil 1 output peak
voltage. Replace the stator coil assembly
if below specification.
1
L
L
Br
Br
NOTE:
• To prevent the engine from starting when
cranking it, be sure to disconnect both
spark plug caps.
• Do not remove the clip from the engine
shut-off switch.
• If measuring the output peak voltage under
the unloaded conditions, disconnect the
connectors.
• When using the manual starter to crank the
engine, the voltage values may vary
depending on the speed at which the
starter handle is pulled.
6AU3K11
r/min
DC V
2. Disconnect the charge coil connectors.
8
3. Measure the charge coil resistance.
Replace if out of specification.
4. Connect the charge coil connectors.
S6AU8039
Ignition and ignition control system
Charge coil output peak voltage:
Brown (Br) – Blue (L)
Unloaded
Loaded
Cranking
1,500
140
160
180
Charge coil resistance (reference
data):
Brown (Br) – Blue (L)
232–348 Ω at 20 °C (68 °F)
1
3,500
180
2
3
4
5
6
7
8
9
8-32