Checking The Rectifier Regulator - SELVA MARINE Pike 9,9 Service Manual

Table of Contents

Advertisement

+
ELEC

Checking the Rectifier Regulator

1. Measure the Rectifier Regulator 1 out-
put peak voltage. Check the Rectifier
Regulator for continuity if the output peak
voltage is below specification.
G/W
G/W
G
NOTE:
• Measure the Rectifier Regulator output
peak voltage with the connector (R) 2 dis-
connected.
• Do not use peak voltage adapter B when
measuring the Rectifier Regulator output
peak voltage.
• Be sure to check the lighting coil before
measuring the Rectifier Regulator output
peak voltage.
Rectifier Regulator output peak
voltage:
Red (R) – Ground
r/min
1,500
DC V
13
2. Disconnect the Rectifier Regulator con-
nector and terminal.
3. Check the Rectifier Regulator for conti-
nuity. Replace if out of specification.
8-39
Electrical system
R
G
B
R
1
2
S6AU8060
Loaded
3,500
13
8
NOTE:
The voltage values given in the table are for
reference only. If voltage is produced, there
is continuity, and, if there is an overload,
there is no continuity. Refer to the table to
determine if there should or should not be
continuity and replace the Rectifier Regulator
if out of specification.
5R
3G/W
4G
6B
b
NOTE:
Be sure to set the measurement range a,
and display the mark b by pushing the
"SHIFT" switch when checking the Rectifier
Regulator continuity.
4G
B6
a
G/W3
G4
R5
S6AU8061
S6S18360
6AU3K11