Troubleshooting The Lower Unit - SELVA MARINE Pike 9,9 Service Manual

Table of Contents

Advertisement

Symptom 1: PT unit does not hold the outboard motor up
Symptom 2

Troubleshooting the lower unit

Symptom 1: Shift mechanism of the forward gear and reverse gear does not operate properly
Symptom 2
6AU3K11
Cause 1
Manual valve left
Manual valve mal-
open
function
Insufficient PT fluid
PT fluid leakage
Air in PT fluid
Clogged fluid pas-
sages
Malfunction of the
PT unit internal
parts
Cause 1
Shift cable and shift
cable joint malfunc-
tion (R model)
Remote control box
malfunction (R
model)
Shift rod cam mal-
function
Detent malfunction
Shift rod operation
Shift rod not con-
malfunction
nected correctly
Shift rod not
adjusted correctly
Shift mechanism
malfunction (in
lower unit)
Troubleshooting the outboard motor
Cause 2
Checking step
Check the manual
valve.
Add sufficient fluid.
Check the PT unit
for leakage.
Bleed the PT unit.
Disassemble and
check the PT unit.
Cause 2
Checking step
Check and adjust
the shift cable and
shift cable joint. (R
model)
Check the remote
control box. (R
model)
Check the shift link
rod.
Check the shift rod
cam.
Check the connec-
tion of the shift rod.
Adjust the shift rod.
Disassemble and
check the lower
unit.
Refer
to
1
page
7-44
3-13
2
7-49
7-52
7-44
3
4
9
Refer
to
5
page
3-10
6
3-10
3-10
7
7-14
6-15
6-37
8
6-15
6-37
6-7
6-27
9
9-8

Hide quick links:

Advertisement

Table of Contents
loading