Creating SIP Factories
The SIP Factory URI must be registered with the SIP server to enable
routing of calls to the SIP Factory. To ensure that the SIP factory is
registered, the option to register Factories must be selected in the Default
IP Network Service.
The maximum of number of SIP Factories that can be defined is:
•
RMX 1500 — 40
•
RMX 2000 — 40
•
RMX 4000 — 80
To create a new SIP Factory:
1
In the RMX Management - Rarely Used pane, click SIP Factories.
2
In the SIP Factories list pane, click the New SIP Factory
The New Factory dialog box opens.
Chapter 5-Entry Queues, Ad Hoc Conferences and SIP Factories
button.
5-13