14 ROM OPERATION FUNCTION
POINT
Even if a DIP switch setting is changed on the way after the power supply on,
"Operation mode" is not changed. Be sure to turn on or reset the power supply of
Multiple CPU system to change a DIP switch setting.
(2) Applicable data into ROM
The data contents batch written to the internal FLASH ROM by ROM writing are
shown below. Backup data except the followings (current position of servomotor in
absolute position system, home position and latch device, etc.) cannot be written
to the internal FLASH ROM.
(a) Content of applicable data into ROM
System setting data
Each parameter for servo control
Servo program
Motion SFC parameter
Motion SFC program
(Note-1) : Mechanical system program and cam data are "applicable data into ROM",
when using the SV22.
SV13
System setting data
Each parameter for servo control
Servo program
Motion SFC parameter
Motion SFC program
Mechanical system program
Cam data
14 - 6
SV22
(Note-1)
(Note-1)