Mitsubishi Electric Q173CPU Programming Manual page 350

Q series motion controller
Hide thumbs Also See for Q173CPU:
Table of Contents

Advertisement

10 MOTION DEVICES
Axis
Device No.
No.
1
#8064 to #8067
2
#8068 to #8071
3
#8072 to #8075
4
#8076 to #8079
5
#8080 to #8083
+0 Servo amplifier type
6
#8084 to #8087
7
#8088 to #8091
8
#8092 to #8095
+1 Motor current
9
#8096 to #8099
+2
10 #8100 to #8103
+3
11 #8104 to #8107
12 #8108 to #8111
13 #8112 to #8115
14 #8116 to #8119
15 #8120 to #8123
16 #8124 to #8127
17 #8128 to #8131
18 #8132 to #8135
19 #8136 to #8139
20 #8140 to #8143
21 #8144 to #8147
22 #8148 to #8151
23 #8152 to #8155
24 #8156 to #8159
25 #8160 to #8163
26 #8164 to #8167
27 #8168 to #8171
28 #8172 to #8175
29 #8176 to #8179
30 #8180 to #8183
31 #8184 to #8187
32 #8188 to #8191
(b) Servo monitor devices (#8064 to #8191)
Information about "servo amplifier type", "motor current" and "motor speed"
for each axis is stored the servo monitor devices.
The details of the storage data are shown below.
(Note-1)
Signal name
0 : Unused
1 : MR-H-BN
2 : MR-J-B
3 : MR-J2-B
Motor speed
-50000 to 50000 ( 0.1[r/min] )
(Note-1) : The value that the lowest servo monitor device No. was added "+0, +1 ···" on each axis is shown.
REMARK
The servo monitor devices (#8064 to #8191) is effective with SW6RN-SV13Q /
SV22Q
(Ver.00D or later).
Signal name
Signal description
4 : MR-J2S-B
5 : MR-J2-M
6 : MR-J2-03B5
65 : FR-V500
-5000 to 5000 ( 0.1[%] )
10 - 5
Refresh cycle
Signal direction
When the servo amplifier
power-on
Monitor device
3.55ms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q173cpunQ172cpuQ172cpun