Mitsubishi Electric Q173CPU Programming Manual page 382

Q series motion controller
Hide thumbs Also See for Q173CPU:
Table of Contents

Advertisement

13 LIMIT SWITCH OUTPUT FUNCTION
1) Without output enable/disable bit/forced output settings
2) With output enable/disable bit/forced output settings
(4) When the multiple watch data, ON region, output enable/disable bit and forced
output bit are set to the same output device, the logical add of output results of the
settings is output.
M9074
Output device
OFF Value
ON region setting
ON Value
Watch data value
Output device
Enable/disable bit
Forced output bit
ON
Output control based on
Output OFF
ON Value and OFF Value
Output control based on
Output OFF
ON Value and OFF Value
13 - 3
Output ON
(Forced output)
Output OFF
Output OFF
Output ON
(Forced output)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q173cpunQ172cpuQ172cpun

Table of Contents