BLOWER CHECK
Perform the blower check in manual blower running state because it is difficult to check blower at automatic control. Blower
is controlled from level l to level 7 equally as in button operation and running logic. In turning on IG, blower relay is ON and
voltage of 0.1 to 1.4V is transferred from FATC connector A-4 terminal to base source of power TR according to FATC
control (selectable from level 1 to level 7). At this time, voltage of blower motor's both ends is determined according to
collector voltage of FATC connector A-5 terminal. If FATC is controlled in level 7, GND(0V) is supplied for FATC
connectorA-18 terminal and high blower relay is driven.
ERROR DIAGNOSTICS
Symptoms
Amount of wind is wrong at manual
selection of blower
Blower wind is discharged despite
pressing OFF switch
http://www.hmaservice.com/viewer/content.asp?IsPrint=true&imgnum=1&print_title...
Causes
Power TR error
Power TR error
How to check
Check voltage of blower motor's both ends.
(Level 1: 3.8V, Level 2: 5.2V, Level 3: 6.5V,
Level 4: 7.9V, Level 5: 9.2V, Level 6: 10.6V,
Level 7: 13.5V [high-relay operation])
Measure voltage of each terminal and if there is
difference more than ±0.6V, check power TR.
Power TR change