Hyundai Tiburon 2003 Workshop Manual page 22

Hide thumbs Also See for Tiburon 2003:
Table of Contents

Advertisement

2. The tester will ask if the battery is connected "IN A VEHICLE" or "OUT OF A VEHICLE".
Make your selection by pressing the arrow buttons; then press ENTER.
3. Choose either CCA or CCP and press the ENTER button.
- CCA : Cold cranking amps, is an SAE specification for cranking batteried at 0°F (-18°C).
- CCP : Cold cranking power, is an SAE specification for korean manufacturer's for cranking batteries
at 0°F (-18°C)
4. Set the CCA value displyed on the screen to the CCA value marked on the battery label by pressing up and
down buttons and press ENTER.
The battery ratings(CCA) displyed on the tester must be identical to the ratings marked on the battery
label.
5. The tester (Micro570) displays battery test results including voltage and battery ratings.
A relevant action must be taken according to the test results by referring to the battery test results as shown in
the table below.
http://www.hmaservice.com/viewer/content.asp?IsPrint=true&imgnum=1&print_title...
Page 2 of 6
24.04.2008

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents