8
REC. (NON-
REC. MODE
AQS type)
FRE. MODE
9
FAN UP/DOWN BLOWER FAN
SPEED
UP/DOWN
10
DEFOG
Rear glass
defogger
SYSTEM CONTROL FEATURES
SIGNAL I/O FOR EACH CONTROL FEATURE
Control item
Required discharge
Auto SW, A/C SW, TEMP SW, INCAR
http://www.hmaservice.com/viewer/content.asp?IsPrint=true&imgnum=1&print_title...
- TEMP: The mode before OFF
- OTHERS: Return to the mode before OFF
• IND ON
1. When operating the REC. S/W from FRE. MODE, fix
the INTAKE DOORto REC. MODE or when operating
• "AUTO"
the REC. S/W from REC., fix the INTAKE DOORto
display
FRE. MODE.
OFF SW AND SYSTEM OPERATION
• IND OFF
- REC.: FRE./REC. MODE CONTROL
• "AUTO"
display
- OFF SW: ALL MODES (POSSIBLE TO MANUALLY
SELECT)
- AUTO: AUTOMATIC CONTROL (FRE. or REC.)
FAN IND
1. BLOWER MOTOR's rotation speed is controlled by the
ON/OFF
current variationof the POWER TRANSISTOR.
2. At AUTO MODE, if FAN is operated UP/DOWN, the
FAN SPEED is UP/DOWNon the basis of the present
FAN LEVEL.
3. At OFF, if the other SW except for "FAN" is turned ON,
the FAN SPEED is gradually increased from LOW to
TARGET SPEED
4. Fan speed level and voltage
• AUTO AIR CONDITIONER: No level (4.5V - B+)
• AUTO HEATER: No level (4.5V - B+)
• MANUAL FAN SPEED: 7th level (3.8V - B+)
5. The first shift to another step takes 0.7 sec. If the
button iscontinually engaged, the first shift takes 0.7
sec. And then the next ones take 0.3 sec per each.
The operation sound is made for 0.1 sec.
6. At MANUAL 7th level when the UP SW is pushed or at
MANUAL 1st level when the DOWN SW is pushed, the
operation sound is made 5 times at an interval of 0.15
sec.
7. When shifting 6 to 7 level, or 2 to 1 level, the operation
soundis intervally made each 0.15 sec.
OFF SW AND SYSTEM OPERATION
- AUTO: AUTO MODE AUTOMATIC CONTROL
- OFF: SYSTEM OFF
- FAN UP/DOWN: BLOWER FAN SPEED MANUAL
CONTROL
DEFOG IND
1. If the DEFOG SW is pushed, the rear glass defogger
ON/OFF
operation signal is output to the ETACS and the
ETACS turns the DEFOG IND on by the HTD input.
2. While operating the rear glass defogger, if DEFOG SW
is pushed, ETACS stops operating the rear glass
defogger and turns the DEFOG IND off.
3. After operating the rear glass defogger for 15 minutes
by EATCS, DEFOG function is automatically off.
OFF SW AND SYSTEM OPERATION
- DEFOG: Push the second DEFOG SW, DEFOG
function is off.
Input
Output
TEMP actuator
Page 4 of 8
Remarks
24.04.2008