Clearing Previous Error Reports - Cisco DS-X9530-SF1-K9 - Supervisor-1 Module - Control Processor Configuration Manual

Mds 9000 family
Table of Contents

Advertisement

Chapter 50
Monitoring System Processes and Logs
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
To perform the required test on a specific module, follow these steps:
Command
Step 1
switch# config terminal
switch(config)#
Note
The following steps can be performed in any order.
Step 2
switch(config)# system health module 8
battery-charger
battery-charger test is not configured to run on
module 8.
Step 3
switch(config)# system health module 8 cache-disk
cache-disk test is not configured to run on
module 8.
Note
The various options for each test are described in the next step. Each command can be configured in any
order. The various options are presented in the same step for documentation purposes.
Step 4
switch(config)# system health module 8 bootflash
System health for module 8 Bootflash is already
enabled.
switch(config)# system health module 8 bootflash
frequency 200
The new frequency is set at 200 Seconds.
Step 5
switch(config)# system health module 8 eobc
System health for module 8 EOBC is now enabled.
Step 6
switch(config)# system health module 8 loopback
System health for module 8 EOBC is now enabled.
Step 7
switch(config)# system health module 5 management
System health for module 8 EOBC is now enabled.

Clearing Previous Error Reports

You can clear the error history for Fibre Channel interfaces, iSCSI interfaces, for an entire module, or
one particular test for an entire module. By clearing the history, you are directing the software to retest
all failed components that were previously excluded from tests.
If you previously enabled the failure-action option for a period of time (for example, one week) to
prevent OHMS from taking any action when a failure is encountered and after that week you are now
ready to start receiving these errors again, the you must clear the system health error status for each test.
Tip
The management port test cannot be run on a standby supervisor module.
Use the EXEC-level system health clear-errors command at the interface or module level to erase any
previous error conditions logged by the system health application. The battery-charger, the bootflash,
the cache-disk, the eobc, the inband, the loopback, and the mgmt test options can be individually
specified for a given module.
OL-6973-03, Cisco MDS SAN-OS Release 2.x
User-driven test for external connectivity verification, port is shutdown during the test (FC ports
only).
User-driven test for internal connectivity verification (Fibre Channel and iSCSI ports).
Online System Health Management
Purpose
Enters configuration mode.
Enables the battery-charger test on both
batteries in the CSM module residing in slot
8. If the switch does not have a CSM in slot
8, this message is issued,
Enables the cache-disk test on both disks in
the CSM module residing in slot 8. If the
switch does not have a CSM in slot 8, this
message is issued,
Enables the bootflash test on Module 8.
Sets the new frequency of the bootflash test
on module 8 to 200 seconds.
Enables the EOBC test on Module 8.
Enables the loopback test on Module 8.
Enables the management test on Module 5.
Cisco MDS 9000 Family Configuration Guide
50-13