Mounting Instructions
ProfiDAT
compact
®
Data Transmission System
Program 0515
Remove worn sliding contact from the insulation:
→ Unscrew the STS-plus 1.4x4-T5 screw with a TX 5 Torx screwdriver (see Fig. 158) and remove the worn
sliding contact (see Fig. 159).
Fig. 158: Loosen STS-plus 1.4x4-T5 screw
Mount new sliding contact (copper graphite: 051592-21 or graphite: 051592-22):
→ Insert the sliding contact (1) into the balance (3) (see Fig. 160).
1
3
Fig. 160: Insert sliding contact (1) into balance (3)
→ Press the copper plate (2) of the sliding contact (1) to the bottom of the balance (3). Ensure that the sliding contact (1) is
correctly centered (4) (see Fig. 160).
2
3
Fig. 161: Copper plate (2) of sliding contact is centered on bottom of balance (3)
MAL0515-0001i-EN
www.conductix.com
2
4
Translated from MAL0515-0001k-DE
Fig. 159: Remove worn sliding contact
Page 128 of 169