Conductix-Wampfler ProfiDAT compact Mounting Instructions page 16

Data transmission system
Hide thumbs Also See for ProfiDAT compact:

Advertisement

Mounting Instructions
ProfiDAT
compact
®
Data Transmission System
Program 0515
2.9.1
Electrical hazards and sources of danger in combination with a conductor rail
Risk of death due to
electrical shock!
Risk of injury due to
falling or being thrown
across the room after an
electrical shock!
Burns due to arcing
resulting from a short
circuit!
MAL0515-0001i-EN
www.conductix.com
Contact with energized components can lead to death or severe injury due to
electrical shock. There is also a risk of injury from shock reactions, falling or
being thrown across the room as a result of an electrical shock.
Work on the following components is dangerous:
Main power supply
Live parts: Line feed, cables, connections, conductor rail, connectors,
collectors, equipment and connections within switching cabinets, control
systems, etc.
Parts that have become live due to a fault
Before working on the parts listed above:
→ Switch off the power supply of the conductor rail system according to the 5
Safety Rules and secure it against being switched on again. For the 5 Safety
Rules, see Section 2.9.
During work:
→ Use insulated tools
Before switching on:
→ Every time before the equipment or system is started, test the insulation
resistance according to locally applicable technical standards, directives and
legal regulations.
→ Carry out locally required electrical tests.
Maintain electrical safety:
→ Regularly test and maintain electrical equipment.
→ If dangerous deficiencies are identified, take measures to correct the
deficiencies without delay. Inform the system operator immediately.
→ If it is not possible to correct the dangerous deficiency, cordon off the area
involved or switch the equipment off and secure it against being switched on
again. Inform the system operator immediately.
→ Immediately secure loose cables and immediately replace damaged cables.
→ Always replace blown fuses with fuses of the same rating.
Translated from MAL0515-0001k-DE
DANGER!
Page 16 of 169

Advertisement

loading
Need help?

Need help?

Do you have a question about the ProfiDAT compact and is the answer not in the manual?

Questions and answers