Download Print this page

Conductix-Wampfler ProfiDAT compact Mounting Instructions page 75

Data transmission system
Hide thumbs Also See for ProfiDAT compact:

Advertisement

Mounting Instructions
ProfiDAT
compact
®
Data Transmission System
Program 0515
3
1
3
Fig. 79: Tighten 4 self-tapping screws (2 Nm)
→ Slide the connector (1) onto ProfiDAT
the connector (1).
→ To avoid an offset in at the connection point (see Fig. 82: Maximum offset of connection point in X-direction and Fig. 83),
insert the mounting aid (2) into the connector point (see Fig. 77). Insert the mounting aid (2) into the ProfiDAT
such a way that it lies flat against the inner surface of the rail (see Fig. 78).
→ Tighten all 4 self-tapping screws (W5154-K30X8-ES) (4) with a torque shut-off screwdriver (e.g. TorqBee) to 2 Nm
(see Fig. 79).
→ Remove the mounting aid (2) from the connection point (see Fig. 80) and connect and mount all ProfiDAT
the same way.
Fig. 81: Fully mounted connection point of rails without offset
ATTENTION!
MAL0515-0001i-EN
www.conductix.com
2
4
compact Rail (3) up to the center. Then slide the second ProfiDAT
®
The two profiles must directly abut each other! The gap between the rails may not be
more than 0.5 mm in the X-direction (travel direction) (see Fig. 82: Maximum offset of
connection point in X-direction )!
The sliding surfaces for the sliding contacts must be level with each other and deburred.
Translated from MAL0515-0001k-DE
3
1
3
4
Fig. 80: Remove mounting aid
2
compact rail (3) into
®
®
compact rail in
®
compact rails in
Page 75 of 169

Advertisement

loading
Need help?

Need help?

Do you have a question about the ProfiDAT compact and is the answer not in the manual?

Questions and answers