Mounting Instructions
ProfiDAT
compact
®
Data Transmission System
Program 0515
ATTENTION!
3.6 Operating conditions
Specification
Ambient temperature
Temperature difference
ATTENTION!
MAL0515-0001i-EN
www.conductix.com
The HF cables must not be crimped (e.g. by pulling too tightly on the cable tie).
→ Observe the bending radii of the HF cables (see Section 3.5.1).
→ Maintain the recommended coupling torques (see Section HF cables 3.5.1).
–20° C up to +55° C
75 K
Faults due to incorrect operating conditions!
Operating conditions outside the specified range can lead to malfunctions due to short
circuits, premature aging and damage to electrical and mechanical components.
Important parameters are:
Dust and deposits
Humidity/condensation
Cold/hot temperatures
Corrosion
Chemical substances
→ The conductor rail system must be switched off if the operating conditions are no longer
within the permissible range described above.
→ The conductor rail system must be switched off if it is wet or soiled. Dry or clean as
specified (see Section 11 for special maintenance instructions for conductor rail systems).
→ Take the relevant measures to restore suitable operating conditions.
Translated from MAL0515-0001k-DE
Value
Conditions: At relative humidity
[50 % rel. at +40° C]
Notes