Conductix-Wampfler Enduro+ Series Manual

Conductix-Wampfler Enduro+ Series Manual

Charging contacts

Advertisement

Quick Links

Charging Contacts
Enduro
Series Manual
+
XA-596511 | 02.26.21
ENDURO
SERIES CHARGING CONTACTS MANUAL
+

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Enduro+ Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Conductix-Wampfler Enduro+ Series

  • Page 1 Charging Contacts Enduro Series Manual XA-596511 | 02.26.21 ENDURO SERIES CHARGING CONTACTS MANUAL...
  • Page 2 Buyer’s name - provided that Seller shall have the right to elect to defend any such suit or action for the account of Buyer. The foregoing shall be the exclusive remedies of the Buyer and all persons and entitles claiming through the Buyer. ENDURO+ SERIES CHARGING CONTACTS MANUAL...
  • Page 3 Ask us for a quote on expert system installations,inspections, preventative maintenance, and repairs/retrofits. As the world’s largest single source manufacturer of mobile electrification products, Conductix-Wampfler has the unique ability to offer a degree of service not found anywhere else. Conductix-Wampfler’s team of highly qualified service technicians and engineers have years of experience servicing our complete line of products.
  • Page 4: Table Of Contents

    Concrete Floor Mounting SECTION 3 - MAINTENANCE System Inspections Brushes Brush Springs Electrical Connections SECTION 4 - STORAGE Packaging Long Term Storage SECTION 5 - TROUBLESHOOTING Troubleshooting SECTION 6 - REPLACEMENT PARTS Replacement Parts CONTACT INFORMATION ENDURO+ SERIES CHARGING CONTACTS MANUAL...
  • Page 5: Section 1 - Safety

    The obligations agreed upon in the delivery agreement and our General Terms and Conditions of business apply, as do the delivery conditions of the manufacturer and the legal regulations applicable at the time the contract was concluded. All products are subject to technical modifications in the context of improvement of function and further development. ENDURO+ SERIES CHARGING CONTACTS MANUAL...
  • Page 6: Personnel Requirements-Qualifications

    Unauthorized persons who do not meet the requirements described here are not acquainted with the dangers in the working area. Keep unauthorized personnel away from the working area. In case of doubt, address the person and direct them away from the working area. Stop working, as long as unauthorized persons are in the working area. ENDURO+ SERIES CHARGING CONTACTS MANUAL...
  • Page 7: Personnel Requirements-Training

    Breathing mask (FFP-3 - according to country-specific requirements): For protection against materials, particles, and organisms. In this case, for protection against the dust produced by the abrasion of carbon brushes and the PVC insulation of the conductor rail. ENDURO+ SERIES CHARGING CONTACTS MANUAL...
  • Page 8: Electrical Warning

    Modification may cause safety and fire hazards, the end user takes sole responsibility for any modifications made to the product and in doing so absolves Conductix-Wampfler from any liability.
  • Page 9: Section 2 - Installation

    Care must be taken when connecting the brush studs to • ensure the correct phases are clustered together. Any Figure 2-3 Top of Collector Showing Clearance Hole and Minimum fault condition resulting from improper installation is the Support Area responsibility of the user. ENDURO+ SERIES CHARGING CONTACTS MANUAL...
  • Page 10: Mounting For Base

    This value may vary based on voltage, enclosure type, and regional standards. Bottom of Base Plate Showing Clearance Holes and Minimum Support Area. Figure: 2-4 Bottom of base showing Clearance Holes, and Minimum Support Area ENDURO+ SERIES CHARGING CONTACTS MANUAL...
  • Page 11: Concrete Floor Mounting

    See Figure 2-6. 6. Drill pilot holes for concrete anchors. Conductix-Wampfler recommends steel drop-in type anchors. See Figure 2-7. 7. Be sure to drill depth of anchor only and hammer with set tool when anchor is flush with top of concrete.
  • Page 12: Section 3 - Maintenance

    10.00-13.15 lbf at minimum compression distance for operation (.5mm from Figure 3-2: Target Mounting Distance at Mid-Stroke free air state) and 18.00-22.50 lbf at maximum compressed distance for operation (20.5mm). See Figure 3-2 ENDURO+ SERIES CHARGING CONTACTS MANUAL...
  • Page 13: Section 4 - Storage

    Store charging contacts or components in a dry environment to prevent the formation of corrosion or oxidation on the contact surfaces. Before use, clean the brush and contact surfaces to remove dirt, oxidation, pitting, and other contaminants via a brass brush or 320 grit sand paper. ENDURO+ SERIES CHARGING CONTACTS MANUAL...
  • Page 14: Section 5 - Troubleshooting

    Inspect the brush pressure, brush, and contact plate Damage to brush or Inspect the contact sets mechanical alignment, reference the supplied drawing for Mechanical alignment contact plate further details Table 5-1 Troubleshooting Problems, Potential Cause, and Solution ENDURO+ SERIES CHARGING CONTACTS MANUAL...
  • Page 15: Section 6 - Replacement Parts

    We recommend that complete base plates and collectors are replaced when worn for optimal operation. Due to the modular design of charging contacts it is recommended to order the part number that is listed on the original component to be replaced. ENDURO+ SERIES CHARGING CONTACTS MANUAL...
  • Page 16: Contact Information

    (+52 81) 1090 9025 (+52 81) 1090 9013 Phone +1-402-339-9300 Phone +1-450-565-9900 +1-402-339-9627 +1-450-951-8591 (+52 81) 1090 9014 Fax (+55 11) 4813 7357 info.br@conductix.com info.us@conductix.com info.ca@conductix.com info.mx@conductix.com latinamerica@conductix.com Contact us for our Global Sales Offices ENDURO+ SERIES CHARGING CONTACTS MANUAL XA-596511 | 02.26.21...