Section 9 16-Bit Timer; Overview; Features - Hitachi H8/3006 Hardware Manual

Table of Contents

Advertisement

9.1

Overview

The H8/3006 and H8/3007 have built-in 16-bit timer module with three 16-bit counter channels.
9.1.1

Features

16-bit timer features are listed below.
• Capability to process up to 6 pulse outputs or 6 pulse inputs
• Six general registers (GRs, two per channel) with independently-assignable output compare or
input capture functions
• Selection of eight counter clock sources for each channel:
Internal clocks: φ, φ/2, φ/4, φ/8
External clocks: TCLKA, TCLKB, TCLKC, TCLKD
• Five operating modes selectable in all channels:
 Waveform output by compare match
Selection of 0 output, 1 output, or toggle output (only 0 or 1 output in channel 2)
 Input capture function
Rising edge, falling edge, or both edges (selectable)
 Counter clearing function
Counters can be cleared by compare match or input capture
 Synchronization
Two or more timer counters (16TCNTs) can be preset simultaneously, or cleared
simultaneously by compare match or input capture. Counter synchronization enables
synchronous register input and output.
 PWM mode
PWM output can be provided with an arbitrary duty cycle. With synchronization, up to
three-phase PWM output is possible

Section 9 16-Bit Timer