Nortel Meridian Meridian 1 Maintenance Manual page 337

Application module and intelligent peripheral equipment module meridian link release 5c/ccr release 3c diagnostic and maintenance guide
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

2010
Log message
Parameters
1: Bad message: missing or wrong information in the request
message
2: Request clash: another Association Table activation was
already underway
3: Load failure: the call processing software could not successfully
load the Association Table into memory
4: Activation failure: the maximum allowable number of active
associations has been exceeded
Description
software failed to complete. The previous version of the Association
Table remains active.
The new associations cannot be used in active call processing
Impact
until the problem has been corrected.
Recovery differs according to the cause.
Recovery
1: Software errorÑlog out and log back into the system; then retry
the installation.
2: This is an attempt to activate more than one table at a time. Find
the log file entries for the activation underway and when it
completes, retry the activation.
3: Call processing was unable to activate the Association Table,
possibly because of shared memory or other memory allocation
problems. Try again later or restart the application.
4: This is an attempt to activate an association table with too many
active associations for the installed CCR package. The active
association limit is displayed in the data section of this log event.
Retry the activation of the association table with active
associations numbering less than or equal to that limit.
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
Chapter 7: CCR log file messages 325
Association Table activation failed
Cause 1, 2, 3, and 4 which have the following meanings
An Association Table activation into the call processing

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meridian 1

Table of Contents