Link control commands

There are two link control commands: enable and disable link. In this
section, bolded text indicates text you input.

enable link

The enable link command puts the specified link in the enabled state. If the
remote end is down, the link remains enabled but down. The normal
response to enable is ÒEnable link link_number: successful.Ó A descriptive
error message is given if the command fails.
Command format:
Example:

disable link

The disable link causes the specified link to go down, and remain down
until it is reenabled. A descriptive error message is given if the command
fails.
Command format:
Example:
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
mlusr> enable link link_number
mlusr> enable link 0
Enable link 0: successful
mlusr>
Link 0 Up
mlusr>
mlusr> disable link link_number
mlusr> disable link 0
Disable Link 0: successful
mlusr>
Link 0 disabled
mlusr>