Nortel Meridian Meridian 1 Maintenance Manual page 474

Application module and intelligent peripheral equipment module meridian link release 5c/ccr release 3c diagnostic and maintenance guide
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

462 Chapter 8: Recovery/replacement procedures
553-3211-510 Standard 1.0 October 1998
Procedure 25: Enable or disable Ethernet LAN support (continued)
Figure 160
Keycode prompt 4
Keycode group 4 (or Q or q to quit):
9
You are prompted to enter the fourth group of keycode characters.
Type the fourth group and press [Return].
Figure 161
Keycode prompt 5
Keycode group 5 (or Q or q to quit):
10
You are prompted to enter the fifth group of keycode characters.
Type the fifth group and press [Return].
A list of configured applications appears.
Note: Optional feature prompts will not appear if the features were
not configured in the keycode. For example, if Meridian Link was not
purchased, the prompts in Figures 162, 163, and 164 will not appear.
Figure 162
Meridian Link protocol prompt
Please enter the Meridian Link protocol, x for X.25, <cr> for TCP/IP):
11
If you are activating the Meridian Link application, you are prompted
to enter the Meridian Link protocol.
If you are using the X.25 protocol, type x, press [Return], then go to
step 14.
If you are using the TCP/IP protocol, press [Return], then go to
step 17.