248 Chapter 5: Application Module and IPE Module error messages
Table 7
maint messages that appear on the console (continued)
Command
Message
ccrstart
CCR ccrlog process is already
(continued)
running.
CCR mmgr process is already
running.
CCR cpexec process is already
running.
CCR reporter process is already
running.
ccrtraffic
Traffic Reporting has been
enabled.
Traffic Reporting has been
disabled.
No CCR Traffic Log files available.
ERROR: the REPORTER process
is not running. Configuration saved
but not enabled until REPORTER
recovers.
ERROR: the REPORTER process
is not running. Configuration saved
but not disabled until REPORTER
recovers.
553-3211-510 Standard 1.0 October 1998
Description
This process was already running
when the system was started. Use
the ccrexit command followed by
ccrstart and the message should not
reappear.
This is after choosing option 2
(Enable traffic reporting) or upon
exit when a user has edited the
configuration without enabling. If the
user responds Yes to enable the
changes, this message will also be
seen.
This is after choosing option 3
(Disable traffic reporting).
No log files are currently available
for viewing.
This will be seen when an enable is
attempted and fails because the
REPORTER is not running.
This will be seen when a disable is
attempted and fails because the
REPORTER is not running.