Change Link - Nortel Meridian Meridian 1 Maintenance Manual

Application module and intelligent peripheral equipment module meridian link release 5c/ccr release 3c diagnostic and maintenance guide
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

104 Chapter 3: Link maintenance commands

change link

553-3211-510 Standard 1.0 October 1998
The change link command modifies link configuration parameters such as
baud rate and timers. Table 4 provides detailed information on each
parameter. Some parameters cannot be changed; these are indicated in the
following description and in Table 4.
!
Command format:
mlusr> change link link_number
The system takes you through each parameter, one at a time, displaying the
parameter name, the valid values or allowed options for the parameter (if
appropriate), and the current value of the parameter.
For each parameter you have three possible options:
1
Enter <cr> (carriage return) to leave the parameter as is.
2
Enter a new value within operational limits.
3
Enter <escape> <cr> to quit change functions.
Values entered outside operational limits are rejected, and you are
prompted for that value again. When you have finished going through all
the parameters appropriate to the link type, you are asked to confirm any
changes you made. Changes are saved in memory and are in effect only
until the next time the system is restarted. See the save link command for
information on saving your changes permanently.
CAUTION
Risk of data loss
Do not use the change link command without the
direction of Nortel support personnel or Host
Computer support.

Hide quick links: