312 Chapter 7: CCR log file messages
553-3211-510 Standard 1.0 October 1998
1010
Log message
overflowing.
Cause 1, 2, or 3, which have the following meanings
Parameters
1: Too many outstanding commands to Meridian 1
2: Too many installed scripts
3: Too many variable tables
The call processing software is overflowing its data
Description
structures.
The impact on the system can differ according to the cause, as
Impact
follows:
1: This condition may point to a communications problem with
Meridian 1.
2: The internal limit (1000) of the number of installed scripts in
the call processing software has been reached.
3: The internal limit (50) of the number of variable tables in the
call processing software has been reached.
Recovery processes also differ according to cause, as
Recovery
follows:
1: Investigate the communications link between Meridian 1 and
the CCR Module to ensure messages are flowing correctly in both
directions. Restarting the application clears the problem
temporarily.
2: Remove scripts that are no longer used for active call
processing.
3: Wait for the call turnover to release old versions of variable
tables kept by the call processing software while active calls
against them still exist. If the problem persists, or there are no
known active calls, restart the application.
Internal data structures in call processing are