Nortel Meridian Meridian 1 Maintenance Manual page 343

Application module and intelligent peripheral equipment module meridian link release 5c/ccr release 3c diagnostic and maintenance guide
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

2017
Log message
reset
Parameters
Description
processing software. The software failed to update the file copy of the
Variable Table after resetting the variable references.
The memory copy of the Variable Table may not be the same
Impact
as the file copy.
Remove all scripts, log out, log back in, activate the
Recovery
Variable Table, and reinstall scripts. If the error persists, shut down
and restart the application. Use the fileverif command to check the file
system integrity.
2018
Log message
memory, and on file
Parameters
Description
processing software. The software failed to reset the variable
references. All of the references should be reset when the system starts
up or after a call processing software failure.
If the user starts to install call scripts, call processing may fail
Impact
the installation because the Variable Table is not active in the call
processing software.
Remove all scripts, log out, log back in, activate the
Recovery
Variable Table and reinstall scripts.
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
Chapter 7: CCR log file messages 331
Fail to write to the Variable Table file: references not
Error status and procedure where the error occurred
This happens during shutdown or restart of the call
Fail to reset references in the Variable Table, in
Error status and procedure where the error occurred
This happens during shutdown or restart of the call

Hide quick links: