Chapter 4: Diagnosing faults

Diagnostic procedure 5: System console fault suspected

Is the console
supported by AM
or IPE Module
applications?
YES
Is the console
powered on?
YES
Console
completes its
start-up self test?
YES
Go to
5.1
553-3211-510 Standard 1.0 October 1998
This procedure applies to the system console only.
NO
NO
NO
Replace the console
with an appropriate
terminal type. See
Note.
Connect the terminal
to a power source
and turn it on.
The terminal is
defective. Replace
the terminal.
Note: The supported
console terminal type is a
DEC VT220 or 100%
compatible terminal (for
example, a PC running
Reflection 4+).