172
Chapter 4: Diagnosing faults
Diagnostic procedure 3
Card fault suspected (Application Module) (continued)
Boot process
gets past ÒTesting
CompleteÓ?
Does ÒConsole
Login:Ó prompt
appear?
Is red LED lit on
the MVME147/167
SBC card?
553-3211-510 Standard 1.0 October 1998
3.2
YES
YES
YES
Replace the
MVME147/167 SBC
NO
card. See Procedure 7:
Replace the
MVME147/167 SBC
card.
Possible operating
system problem. Install
NO
the latest version of the
operating system. See
Procedure 19 or 20,
depending on the type
of SBC card youÕre
using.
NO
Replace the
MVME147/167 SBC card.
See Procedure 7: Replace
the MVME147/167 SBC
card.
Stop