112 Chapter 3: Link maintenance commands
Table 4
Link parameters (continued)
Link parameter
Lowest LCN*
Highest LCN*
LOC LIC*
HOC HIC*
T10
T11
553-3211-510 Standard 1.0 October 1998
Allowed values
(defaults in parentheses)
1
4095
-1
-1
0Ð(1800)Ð9999
0Ð(2000)Ð9999
Ñ continued Ñ
* Parameters marked with an asterisk (*) cannot be changed.
Description
Specifies the lowest X.25 virtual
circuit number that will be assigned
for an incoming/outgoing X.25 call
request. Default value is 1.
Specifies the highest X.25 virtual
circuit number that will be assigned
for an incoming/outgoing X.25 call
request. Default value is 4095.
Specifies the lowest X.25 virtual
circuit number that will be assigned
for an incoming (if DCE) or outgoing
(if DTE) X.25 call request. Not used
by the AM or IPE Module. Default
value is -1.
Specifies the highest X.25 virtual
circuit number that will be assigned
for an incoming (if DCE) or outgoing
(if DTE) X.25 call request. Not used
by the AM or IPE Module. Default
value is -1.
Amount of time (in 1/10 second
increments) the AM or IPE Module
will wait for an X.25 restart
confirmation packet after sending an
X.25 restart packet to host.
Amount of time (in 1/10 second
increments) the host will wait for an
X.25 call accept packet after
sending an X.25 call request packet
to the AM or IPE Module.