Diagnostic procedure 5
System console fault suspected (continued)
5.5
ÒConsole LoginÓ appears
when you press Break?
See Note.
YES
Stop
One or more of these are defective. Replace each item in turn until
output appears at the system console:
¥ cable from Application Module or IPE Module to system console
¥ console terminal
¥ MVME147/167 SBC card (Application Module only)
¥ MVME712 transition card (Application Module only)
¥ Application Module
¥ IPE Module
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
NO
Go to
5.6
Note: Repeat this step six to eight times to cycle
through different baud rates, but be careful not to
press the Break key too quickly in succession. If
the ÒConsole LoginÓ prompt appears and you press
the Break key again, you will have to keep pressing
Break another six to eight times until the prompt
appears again.
5.6
Chapter 4: Diagnosing faults 183