2043
Log message
Parameters
3: A system error occurred.
Description
to a system problem.
The CDN is released from the MSL-1 point of view. All calls
Impact
to this CDN will be defaulted.
The user needs to remove the CDN from the Association
Recovery
Table as well. If this is unsuccessful, CCR needs to be restarted.
2044
Log message
Parameters
9, 10, and 11
1. Bad Device ID
2. Bad DN
3. Invalid VC Class
4. Invalid ACD Position ID
5. Device is currently locked by another application
6. Cannot initialize device
7. Device already acquired by application
8. Device already monitored by application
9. Bad customer number
10. Invalid reason
11. Device locked by application
Description
cause in the Cause field.
Since the acquire was not successful, the CDN cannot be used.
Impact
Look at the cause field of the error message to find out the
Recovery
reason. Try to remove the CDN and reenter it after the problem has
been corrected. If this does not work, restart the CCR application.
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
Chapter 7: CCR log file messages 343
CDN is de-acquired by tsmain
Component, Object, Function, Cause 3
The CDN has been released forcefully by the system due
CDN acquire error occurred
Component, Object, Function, Cause 1, 2, 3, 4, 5, 6, 7, 8,
The CDN acquire request for a CDN failed due to the