448 Chapter 8: Recovery/replacement procedures
553-3211-510 Standard 1.0 October 1998
Procedure 22: Load the application software from tape (continued)
Figure 137
Verification prompt
Saving default subnet mask:
The following will be installed:
Meridian Link
Large CCR
The following packages are configured:
1
96
97
98
99
100
101
Ethernet NSE software is enabled.
Is this correct (y/n/q)?
The system lists the application or applications installed.
Note: Figure 137 only shows applications that have been selected;
they are actually enabled when the system reboots at the end of this
procedure.
19
The system prompts you to verify that the list is correct.
To check that the correct application has, or applications have,
been activated, refer to the checklist (Table 12) you completed in
Chapter 6, ÒSite survey/installation checklistÓ of the Meridian
Link/Customer Controlled Routing Installation and Upgrade Guide
(NTP 553-3202-210).
If the list is incorrect, type n and press [Return]. You are returned to
step 10. If the list is correct, type y and press [Return].
If you did not purchase CCR or NSE, go to step 25.
If you did not purchase CCR but you have enabled NSE, go to step
21. For more information about Ethernet connections, refer to
ÒInstalling Ethernet LAN supportÓ in Chapter 9, ÒMeridian Link/CCR
interface cablingÓ of the Meridian Link/Customer Controlled Routing
Installation and Upgrade Guide (NTP 553-3202-210).
If you have purchased CCR, go to step 20.