Ecowatt
Drive K320 series
®
16:02:35
Forward
P01.00:Running mode of start
P01.01:Starting frequency of direct start
P01.02:Hold-up time of starting frequency
P01.03:Brake current before start
P01.04:Brake time before start
P01.05:Acceleration/deceleration mode selection
Return
Press
key to enter addition interface, and press
confirm the addition operation. If this parameter is not included in the original "common
parameter setup" list, the newly-added parameter will be at the end of the list; if this
parameter is already in the "common parameter setup" list, the addition operation will be
invalid. If
key or
to parameter setup list menu.
All the function code groups under parameter setup sub-menu can be added to "common
parameter setup" list. Up to 64 function codes can be added to the "common parameter setup"
list.

5.4.5 Parameter selection edit interface

In the fourth-level menu of "parameter setup" menu, press
enter parameter selection edit interface. After entering edit interface, current value will be
highlighted. Press
corresponding parameter item of current value will be highlighted automatically. After
parameter selection is done, press
return to the previous menu. In parameter selection edit interface, press
maintain the parameter value and return to the previous menu.
16:02:35
Forward
Local Ready
P00.00:Speed control mode
P00.01:Running command channel
P00.02:Communication command channel
P00.03:Max. output frequency
P00.04:Upper limit of running frequency
P00.05:Lower limit of running frequency
Return
Add
In parameter selection edit interface, the "authority" on the top right indicates whether this
parameter is editable or not.
"√" indicates the set value of this parameter can be modified under current state.
"×" indicates the set value of this parameter cannot be modified under current state.
"Current value" indicates the value of current option.
"Default value" indicates the default value of this parameter.
Local Ready
01: K320
Add
Select
Figure 5-14 Add parameter diagram 2
key is pressed without selecting addition operation, it will return
key and
01: K320
Current
0:SVC 0
1:SVC 1
2:V/F mode
3:VC mode
Return
Select
Figure 5-15 Parameter selection edit interface
16:02:35
Return
key to edit current parameter value, and the
key or
key to save the selected parameter and
value:0
Default value:2
Authority:√
Homepage
Confirm
-43-
Basic operation guidelines
Forward
Local
Ready
01: K320
Sure to add to common parameter
setup?
Homepage
key,
key or
key,
key or
Current
value:1
Default value:2
1:SVC 1
2:V/F mode
3:VC mode
Return
Homepage
Confirm
key to
key to
key to
Authority:√
Confirm