Kruger Ecowatt K320 Series Operation Manual page 169

Variable frequency drive
Hide thumbs Also See for Ecowatt K320 Series:
Table of Contents

Advertisement

Ecowatt
Drive K320 series
®
Function
Name
code
Pull-in current 2
P04.35
in SM V/F control
Frequency
threshold for
P04.36
pull-in current
switching in SM
V/F control
Reactive current
closed-loop
P04.37
proportional
coefficient in SM
V/F control
Reactive current
closed-loop
P04.38
integral time in
SM V/F control
Reactive current
closed-loop output
P04.39
limit in SM V/F
control
Enabling IF mode
P04.40
for AM 1
Description
When the SM V/F control mode is enabled,
the function code is used to set the
reactive current of the motor when the
output frequency is higher than the
frequency specified by P04.36
Setting range: -100.0%–100.0% (of the
motor rated current)
When the SM V/F control mode is enabled,
the function code is used to set the
frequency threshold for the switching
between pull-in current 1 and pull-in
current 2.
Setting range: 0.00Hz–P00.03 (Max. output
frequency)
When the SM V/F control mode is enabled,
the function code is used to set the
proportional coefficient of reactive current
closed-loop control.
Setting range: 0–3000
When the SM V/F control mode is enabled,
the function code is used to set the
integral coefficient of reactive current
closed-loop control.
Setting range: 0–3000
When the SM V/F control mode is enabled,
the function code is used to set the output
limit of the reactive current closed-loop
control. A greater value indicates a higher
reactive closed-loop compensation voltage
and higher output power of the motor. In
general, you do not need to modify the
function code.
Setting range: 0–16000
0: Disable
1: Enable
-160-
Function parameter list
Default Modify
10.0%
50.00Hz
50
30
8000
0