Kruger Ecowatt K320 Series Operation Manual page 90

Variable frequency drive
Hide thumbs Also See for Ecowatt K320 Series:
Table of Contents

Advertisement

Ecowatt
Drive K320 series
®
Function
code
Starting frequency hold
P01.02
Braking current before
P01.03
DC braking time before
P01.04
P01.05
ACC and DEC mode
P01.08
Starting frequency of DC
P01.09
Wait time before DC
P01.10
DC braking current for
P01.11
P01.12
DC braking time for stop 0.00–50.00s
FWD/REV running
P01.13
FWD/REV running
P01.14
P01.15
Stop speed detection
P01.16
Terminal-based running
P01.18
command protection at
Action selected when
running frequency less
than frequency lower
P01.19
limit (valid when
frequency lower limit
Name
time
start
start
Stop mode
braking for stop
braking for stop
stop
deadzone time
switching mode
Stop speed
mode
power-on
greater than 0)
Description
0.0–50.0s
0.0–100.0%
0.00–50.00s
0: Linear
1: S curve
Note: If mode 1 is selected, set P01.06,
P01.07, P01.27, and P01.28 accordingly.
0: Decelerate to stop
1: Coast to stop
0.00Hz–P00.03
frequency)
0.00–50.00s
0.0–100.0%
0.0–3600.0s
0: Switch at zero frequency
1: Switch at the starting frequency
2: Switch after the speed reaches the
stop speed with a delay
0.00–100.00Hz
0: Detect by the set speed (unique in
space voltage vector control mode)
1: Detect by the feedback speed
0: The terminal running command is
invalid at power-on
1: The terminal running command is
valid at power-on
0: Run at the frequency lower limit
1: Stop
2: Sleep
-81-
Basic operation guidelines
(Max.
output
Default
0.0s
0.0%
0.00s
0
0
0.00Hz
0.00s
0.0%
0.00s
0.0s
0
0.50 Hz
1
0
0