Ecowatt
Drive K320 series
®

5.4.2 List edit

The monitoring items displayed in the parameter list of stop state can be added by users as
needed (through the menu of the function code in state check group), and the list can also be
edited by users e.g. "shift up", "shift down" and "delete from the list". The edit function is
shown in the interface below.
16:02:35
Forward
Local
Ready
Parameter displayed in stop state
Parameter displayed in running state
Return
Homepage
Press
key to enter edit interface, select the operation needed, and press
key or
key to confirm the edit operation and return to the previous menu (parameter list),
the returned list is the list edited. If
selecting edit operation, it will return to the previous menu (parameter list remain
unchanged).
Note: For the parameter objects in the list header, shift-up operation will be invalid, and the
same principle can be applied to the parameter objects in the list footer; after deleting a certain
parameter, the parameter objects under it will be shifted up automatically.
The monitoring items displayed in the parameter list of running state can be added by users
as needed (through the menu of the function code in state check group), and the list can also
be edited by users e.g. "shift up", "shift down" and "delete from the list". The edit function is
shown in the interface below.
16:02:35
Forward
Local
Ready
Parameter displayed in stop state
Parameter displayed in running state
Return
Homepage
The parameter list of common parameter setup can be added, deleted or adjusted by users as
needed, including delete, shift-up and shift-down; the addition function can be set in a certain
function code of a function group. The edit function is shown in the figure below.
16:02:35
Forward
Local
Ready
Common parameter
setup
Parameter setup
State monitoring/fault
record
Motor parameter
autotuning
Parameter backup/restore
to default value
System setting
Return
Homepage
01: K320
16:02:35
P17.00:Set frequency
P17.11:DC bus voltage
P17.12:Digital input terminal state
P17.13:Digital output terminal state
P17.23:PID reference value
P17.24:PID feedback value
Return
Select
Figure 5-10 List edit diagram 1
16:02:35
01: K320
P17.01:Output frequency
P17.00:Set frequency
P17.11:DC bus voltage
P17.03:Output voltage
P17.04:Output current
P17.05:Motor speed
Return
Select
Figure 5-11 List edit diagram 2
16:02:35
01: K320
P00.10:Keypad setting frequency
P00.00:Speed control mode
P00.11:Acceleration time 1
P00.12:Deceleration time 1
P00.01:Running command channel
P00.13:Running direction selection
Return
Select
Figure 5-12 List edit diagram 3
Forward
01: K320
Local
Ready
Edit
Confirm
key or
key is pressed in edit interface wihouth
Forward
01: K320
Local
Ready
Edit
Confirm
Forward
Local
Ready
01: K320
Edit
Select
-41-
Basic operation guidelines
16:02:35
Forward
Local
Ready
Shift up
Shift down
Delete from the list
Return
Homepage
key,
16:02:35
Forward
Local
Ready
Shift up
Shift down
Delete from the list
Return
Homepage
16:02:35 Forward
Local
Ready
Shift up
Shift down
Delete from the list
Return
Homepage
01: K320
Select
01: K320
Select
01: K320
Select