Ecowatt
Drive K320 series
®
Function
Name
code
Setting source of
reverse rotation
upper-limit
P03.15
frequency in
torque control
Forward rotation
upper-limit
P03.16
frequency set
through keypad in
torque control
Reverse rotation
upper-limit
P03.17
frequency set
through keypad in
torque control
Setting source of
P03.18
electromotive
torque upper limit
Setting source of
P03.19
braking torque
upper limit
Electromotive
torque upper limit
P03.20
set through
keypad
Description
0: Keypad (P03.17)
1–11: Same as those of P03.14
The function codes are used to set the
frequency upper limits. 100% corresponds
to the max. frequency. P03.16 sets the
value when P03.14=1; P03.17 sets the value
when P03.15=1.
Setting range: 0.00Hz–P00.03 (Max. output
frequency)
0: Keypad (P03.20)
1: AI1
2: AI2
3: AI3
4: Pulse frequency HDIA
5: Modbus communication
6:
PROFIBUS/CANopen/DeviceNet
communication
7: Ethernet communication
8: Pulse frequency HDIB
9: EtherCAT/PROFINET communication
10: PLC
11: Reserved
Note: For setting sources 1–4 and 8, 100%
corresponds to three times the rated motor
current.
0: Keypad (P03.21)
1–10: Same as those for P03.18
The function codes are used to set torque
limits.
Setting range: 0.0–300.0% (of the motor
rated current)
-150-
Function parameter list
Default Modify
0
50.00Hz
50.00Hz
0
0
180.0%