code
P14.10–
Reserved
P14.24
P15 group––Functions of communication expansion card
Function
Name
code
P15.00–
See the communication expansion card operation manual.
P15.27
Master/slave CAN
communication
P15.28
address
Master/slave CAN
communication
P15.29
baud rate selection
Master/slave CAN
communication
P15.30
timeout time
P15.31–
See the communication expansion card operation manual.
P15.69
P16 group––Functions of communication expansion card
Function
Name
code
P16.00–
See the communication expansion card operation manual.
P16.23
Time for
identifying
P16.24
expansion card at
slot 1
Time for
identifying
P16.25
expansion card at
slot 2
Time for
identifying
P16.26
expansion card at
slot 3
Description
Description
0–127
0: 50Kbps
1: 100 Kbps
2: 125Kbps
3: 250Kbps
4: 500Kbps
5: 1M bps
0.0 (invalid)–300.0s
Description
0.0–600.0s
If it is set to 0.0, identifying faults are not
detected.
0.0–600.0s
If it is set to 0.0, identifying faults are not
detected.
0.0–600.0s
If it is set to 0.0, identifying faults are not
detected.
-211-
Function parameter list
Default Modify
Default Modify
1
2
0.0s
Default Modify
0.0s
0.0s
0.0s