Figure 3-4 Main circuit diagram for 160P and higher models
Note:
160P and higher models can be connected to external DC reactors. Before connection, take
off the copper bar between P1 and (+). 090P and higher models can be connected to
external braking units. DC reactors and braking units are optional parts.
022P–132P models are equipped with built-in DC reactors.
045P and lower models carry built-in braking units. Braking units are optional parts for
055P–075P models and they can be built in or externally connected to the models.

3.3 Product specifications

Function description
Power input
Input frequency (Hz) 50Hz or 60Hz, allowable range: 47–63Hz
(+)
(-)
Figure 3-3 Main circuit diagram for 055P–132P
DC reactor
P1
Input voltage (V)
Input current (A)
(+)
(-)
AC 3PH 380V (-15%)–440V (+10%)
See "Product ratings".