Ecowatt
Drive K320 series
®
Function
code
Voltage set
P04.28
through keypad
Voltage increase
P04.29
Voltage decrease
P04.30
Max. output
P04.31
Min. output
P04.32
Weakening
coefficient in
P04.33
constant power
Pull-in current 1
P04.34
in SM V/F control
Pull-in current 2
P04.35
in SM V/F control
Frequency
threshold for
pull-in current
P04.36
switching in SM
V/F control
Reactive current
closed-loop
P04.37
proportional
coefficient in SM
V/F control
Name
0.0%–100.0%(of the motor rated voltage)
0.0–3600.0s
time
0.0–3600.0s
time
P04.32–100.0% (of the motor rated voltage)
voltage
0.0%–P04.31 (the motor rated voltage)
voltage
1.00–1.30
zone
When the SM V/F control mode is enabled,
the function code is used to set the reactive
current of the motor when the output
frequency is lower than the frequency
specified by P04.36.
Setting range
rated current)
When the SM V/F control mode is enabled,
the function code is used to set the reactive
current of the motor when the output
frequency is higher than the frequency
specified by P04.36.
Setting range
rated current)
When the SM V/F control mode is enabled,
the function code is used to set the frequency
threshold for the switching between pull-in
current 1 and pull-in current 2.
Setting range
frequency)
When the SM V/F control mode is enabled,
the function code is used to set the
proportional coefficient of reactive current
closed-loop control.
Setting range: 0–3000
Description
:
-100.0%–100.0% (of the motor
:
-100.0%–100.0% (of the motor
:
0.00Hz–P00.03 (Max. output
-67-
Basic operation guidelines
Default
100.0%
5.0s
5.0s
100.0%
0.0%
1.00
20.0%
10.0%
50.00Hz
50