Ecowatt
Drive K320 series
®
Function
Name
code
Description
FWD
K1
REV
K2
COM
2: Three-wire control 1. This mode defines
Sin as the enabling terminal, and the
running command is generated by FWD,
while the direction is controlled by REV.
During running, the Sin terminal needs to
be closed, and terminal FWD generates a
rising edge signal, then the VFD starts to
run in the direction set by the state of
terminal REV; the VFD needs to be stopped
by disconnecting terminal Sin.
SB1
SB2
K
The direction control is as follows during
running:
Previous
Sin
REV
direction
Run
OFF→
forward
ON
ON
Run
reversely
Run
ON→
reversely
ON
OFF
Run
forward
ON
ON→
OFF
OFF
Sin: Three-wire control; FWD: Forward
running; REV: Reverse running
-165-
Running
FWD REV
command
OFF
OFF
Stop
Forward
ON
OFF
running
OFF
ON
Stop
Reverse
ON
ON
running
FWD
SIn
REV
COM
Present
direction
Run reversely
Run forward
Run forward
Run reversely
Decelerate to stop
Function parameter list