Kruger Ecowatt K320 Series Operation Manual page 107

Variable frequency drive
Hide thumbs Also See for Ecowatt K320 Series:
Table of Contents

Advertisement

Ecowatt
Drive K320 series
®
Setting
Function
Switch between motor 1
35
and motor 2
Switch the running
36
command channel to
Switch the running
37
command channel to
Switch the running
38
command channel to
communication
39
Pre-exciting command
Clear electricity
40
consumption
Keep electricity
41
consumption
Switch the setting source
42
of braking torque upper
limit to keypad
Position reference point
43
Disable spindle
44
orientation
Spindle zeroing / Local
45
positioning zeroing
Spindle zero position
46
selection 1
Spindle zero position
47
selection 2
Spindle scale division
48
selection 1
When the function is valid, the switchover between the
two motors can be controlled.
When the function is enabled, the running command
channel is switched to keypad. When the function is
disabled, the running command channel is restored to
keypad
the previous setting.
When the function is enabled, the running command
channel is switched to terminal. When the function is
disabled, the running command channel is restored to
terminal
the previous setting.
When the function is enabled, the running command
channel is switched to communication. When the
function is disabled, the running command channel is
restored to the previous setting.
When this terminal is valid, motor pre-exciting is
started and continues until this terminal becomes
invalid.
When this command becomes valid, the electricity
consumption quantity of the VFD is cleared.
When this command is valid, the present running of the
VFD has no impact on the electricity consumption
quantity.
When this command is valid, the upper limit of the
torque is set through the keypad.
Valid only for S1, S2, and S3.
input
Used to disable spindle orientation.
Used to trigger and enable spindle orientation.
Spindle zero position selection 1 made through
terminals
Spindle zero position selection 2 made through
terminals
Spindle scale division selection 1 made through
terminals
Description
-98-
Basic operation guidelines

Advertisement

Table of Contents
loading

Table of Contents