Kruger Ecowatt K320 Series Operation Manual page 342

Variable frequency drive
Hide thumbs Also See for Ecowatt K320 Series:
Table of Contents

Advertisement

Ecowatt
Drive K320 series
®
A.7.6 Simplified incremental PG card——EC-PG507-12
The terminals are arranged as follows:
The DIP switch SW1 is used to set the voltage class (5 V or 12 V) of the power supply of the
encoder. The DIP switch can be operated with an auxiliary tool.
PE
PGND
Indicator definition:
Indicator
LED1
Disconnection
LED2
LED3
EC-PG507-12 can work in combination with multiple types of incremental encoders through
various external wiring modes, which are similar to the wiring modes of EC-PG505-12.
EC-PG507-12 terminals are described as follows:
Signal
PWR
PGND
A1+
A1-
B1+
B1-
Z1+
Z1-
A1+
A1-
Name
This indicator is on when the expansion card is establishing
a connection with the control board; it blinks periodically
Status
after the expansion card is properly connected to the control
indicator
board (the period is 1s, on for 0.5s, and off for the other 0.5s);
and it is off when the expansion card is disconnected from
the control board.
This indicator is off when A1 and B1 of the encoder are
indicator
disconnected; it is on when the encoder pulses are normal.
Power
This indicator is on after the control board feeds power to the
indicator
PG card.
Port
Encoder power
Encoder interface
B1+
B1-
Voltage: 5V/12V ± 5%
Max. current: 150 mA
The voltage class can be selected through SW1,
depending on the encoder voltage class.
(PGND is the isolation power ground.)
1. Supporting push-pull interfaces of 5 V/12 V
2. Supporting open collector interfaces of 5 V/12 V
3. Supporting differential interfaces of 5 V
4. Response frequency: 400 kHz
5. Support the encoder cable length of up to 50 m
-333-
Z1+
Z1-
Function
Function
Expansion cards
PWR
PGND

Advertisement

Table of Contents
loading

Table of Contents