Motor Parameter Autotuning; Parameter Backup - Kruger Ecowatt K320 Series Operation Manual

Variable frequency drive
Hide thumbs Also See for Ecowatt K320 Series:
Table of Contents

Advertisement

Ecowatt
Drive K320 series
®

5.4.8 Motor parameter autotuning

In "Motor parameter autotuning" menu, press
parameter autotuning selection interface, however, before entering motor parameter
autotuning interface, users must set the motor nameplate parameters correctly. After entering
the interface, select motor autotuning type to carry out motor parameter autotuning. In motor
parameter autotuning interface, press
16:02:35
Forward
Local
Ready
Common parameter setup
Parameter setup
State monitoring/fault record
Motor parameter autotuning
Parameter backup/restore to default value
System setting
Return
Homepage
After selecting motor autotuning type, enter motor parameter autotuning interface, and press
RUN key to start motor parameter autotuning. After autotuning is done, a prompt will pop out
indicating autotuning is succeeded, and then it will return to the main interface of stop.
During autotuning, users can press STOP/RST key to terminate autotuning; if any fault occur
during autotuning, the keypad will pop out a fault interface.
16:02:35
Forward
Autotuning step:1
In parameter autotuning
Return

5.4.9 Parameter backup

In "parameter backup" menu, press
parameter backup setting interface and function parameter restoration setup interface to
upload/download VFD parameters, or restore VFD parameters to default value. The keypad has
three different storage areas for parameter backup, and each storage area can save the
parameters of one VFD, namely it can save parameters of three VFD in total.
16:02:35
Forward
Local
Ready
Common parameter setup
Parameter setup
State monitoring/fault record
Motor parameter autotuning
Parameter backup/restore to default value
System setting
Return
Homepage
16:02:35
01: K320
Ensure motor nameplate parameters are set
correctly!
Return
Select
Figure 5-18 Parameter autotuning operation diagram
Local
Run
01: K320
Homepage
Figure 5-19 Parameter autotuning finished
16:02:35
01: K320
Operate the storage area 1: BACKUP01
Operate the storage area 2: BACKUP02
Operate the storage area 3: BACKUP03
Restore function parameter to default value
Return
Select
Figure 5-20 Parameter backup operation diagram
key,
key or
Forward
Local
Ready
01: K320
Add
Confirm
16:02:35
Autotuning step:3
In parameter autotuning
Return
Stop
key,
key or
Forward
Local
Ready
01: K320
Edit
Select
-45-
Basic operation guidelines
key or
key to enter motor
key to return to the previous menu.
16:02:35
Forward
Complete parameter rotary autotuning
Complete parameter static autotuning
Partial parameter static autotuning
Return
Forward
Local
Run
Homepage
key to enter function
Forward
16:02:35
Upload local function parameters to keypad
Download complete keypad function parameters
Download keypad function parameters not in motor
group
Download keypad function parameters in motor group
Return
Local
Ready
01: K320
Homepage
Confirm
01: K320
Stop
Local
Ready
01: K320
Homepage
Select

Advertisement

Table of Contents
loading

Table of Contents