Kruger Ecowatt K320 Series Operation Manual page 181

Variable frequency drive
Hide thumbs Also See for Ecowatt K320 Series:
Table of Contents

Advertisement

Ecowatt
Drive K320 series
®
Function
Name
code
Y1 switch-on
P06.06
delay
Y1 switch-off
P06.07
delay
HDO switch-on
P06.08
delay
HDO switch-off
P06.09
delay
RO1 switch-on
P06.10
delay
RO1 switch-off
P06.11
delay
RO2 switch-on
P06.12
delay
RO2 switch-off
P06.13
delay
P06.14
AO1 output
P06.15
Reserved
HDO high-speed
P06.16
pulse output
Description
The function codes specify the delay time
corresponding
to
changes when the programmable output
terminals switch on or switch off.
Y electric level
Invalid
Y valid
Switch on
delay
Setting range: 0.000–50.000s
Note: P06.08 and P06.09 are valid only
when P06.00=1.
0: Running frequency (0–Max. output
frequency)
1: Set frequency (0–Max. output frequency)
2: Ramp reference frequency (0–Max.
output frequency)
3:
Rotational
corresponding to max. output frequency)
4: Output current (0–Twice the VFD rated
current)
5: Output current (0–Twice the motor rated
current)
6: Output voltage (0–1.5 times the VFD
rated voltage)
7: Output power (0–Twice the motor rated
power)
8: Set torque (0–Twice the motor rated
current)
9: Output torque (Absolute value, 0–+/-
Twice the motor rated torque)
10: AI1 input (0–10V/0–20mA)
-172-
the
electrical
level
invalid
Valid
Switch off
delay
speed
(0–Speed
Function parameter list
Default Modify
0.000s
0.000s
0.000s
0.000s
0.000s
0.000s
0.000s
0.000s
0
0
0